Single Flange Smart Pressure Sensor/Transmitter

I Product IntroductionThe smart remote pressure transmitter is mainly applied to prevent the media in the pipeline directly into the transmitter\'s pressure sensor components. The flange is linked to the transmitter by capillary filled with fluid. It also can communicate with HART manipulator, and set or monitor via it.Applicati

Featured Products

I Product Introduction
The smart remote pressure transmitter is mainly applied to prevent the media in the pipeline directly into the transmitter's pressure sensor components. The flange is linked to the transmitter by capillary filled with fluid. It also can communicate with HART manipulator, and set or monitor via it.

Application
Measuring depositing medium with solid granules or suspended matter.

Eliminating the leakage of connecting pipe to pollute the surrounding environment; Avoiding the heavy works of frequently adding spacer liquid because of unstable signal, in the time of using spacer liquid.

Measuring interface and density continuously and precisely to get the real changes of process.

Such as in food, beverage and medical industry fields, the connecting medium part of transmitter not only should meet hygienic standards, but also should be cleaned easily to prevent cross contamination of different mediums.

II Performance Specifications
Zero shift volume
Maximum positive shift volume: difference between migration volume upper range and measuring range
Maximum negative shift volume: lower than air pressure

Measuring range
Lower range limit: -100%URL (≥-0.1%MPa)~ +100%URL-Span
Upper range limit: -100%URL+Span (≥-0.1%MPa+ Span)~+100%URL

Measuring range and zero adjustment
HART manipulator, local button, communication software supported by HART protocol.


 
Measuring object: liquid, vapor and gas
Operating Temperature Range:  -40ºC ~ 85ºC
Accuracy:  0.1% F.S
Range down: 10:1
Insulation resistance: >100MΩ (100VDC)
Damping value: 0.1~16s (Option)
EMC:  EN 61326-1:2013
Output signal:  4~20mA(Max 22mA,Min 3.8mA)
Communication interface:  HART
Intrinsic safety:  EX ia IIC T6
Enclosure rating: IP 68

Single Flange Smart Pressure Transducer/Transmitter
Single Flange Smart Pressure Transducer/Transmitter
III Structural Drawing


Single Flange Smart Pressure Transducer/Transmitter

Single Flange Smart Pressure Transducer/Transmitter
Single Flange Smart Pressure Transducer/Transmitter
Single Flange Smart Pressure Transducer/Transmitter

V Selection Guide
 
Code 1
RN
RS
Basic type
Without capillary
With capillary
Code 2
C
D
J
E
F
K
G
H
Q
R
M
S
T
N
U
W
Nominal diameter & pressure rating of remote flange
DN 2″ Class 150 lb
DN 2″ Class 300 lb
DN 2″ Class 600 lb
DN 3″ Class 150 lb
DN 3″ Class 300 lb
DN 3″ Class 600 lb
DN 4″ Class 150 lb
DN 4″ Class 300 lb
DN 50 PN 1.6MPa/4MPa
DN 50 PN 6.4MPa
DN 50 PN 10MPa
DN 80 PN 1.6MPa/4MPa
DN 80 PN 6.4MPa
DN 80 PN 10MPa
DN 100 PN 1.6MPa
DN 100 PN 4MPa
Code 3 
A
B
C
Remote flange isolating diaphragm
316L SST
Hastelloy C
Tantalum (Only flat flange)
Code 4
0
1
2
3
Insert tube length (mm)
0 (Flat flange)
50
100
150
Code 5
A
B
Filling liquid
Ordinary silicone oil(-30~200ºC)
High temperature silicone oil(-10~350ºC)
Code 6
0
1
2
3
4
5
6
8
X
Capillary Length
No Capillary
1m
2m
3m
4m
5m
6m
8m
Special length
Code 7
N
P
Capillary protective cover
None
With PVC protective cover
Note: (1) In the choice of remote flange sealing device, you
should firstly complete the selection of ASP2002B Smart
Remote Pressure Transmitter and select in the
ASP2002B intelligent differential pressure transmitter
selection table: Code 5 - R remote options.
(2) The accuracy grade level of level and remote
transmitter is 0.25 class
Example:
Smart Remote Pressure Transmitter
ASP2002BH-4R2N2C-MiP, RHFA2A3P
[B]: Accuracy: 0.1%F.S
[H]: Output: (4~20) mA & HART
[4]: Measuring range : 0-4.0 ~ 40 kPa
[R]: Process connection : Remote
[2]: Isolating diaphragm:316L stainless steel
[N]: O-ring material process flange:
Perbunan(NBR)
[2]: Mounting Bracket: Stainless steel bracket
[C]: Nameplate: In Chinese
[M]: LCD display meter
[i]: Intrinsic safety Ex ia IIC T4~T6
[P]: Stainless steel tag label
[RH]: With capillary, flange sealing device of high side
[F]: Nominal diameter & pressure rating of remote
flange: 
DN 3″ Class 300 lb
[A]: Remote flange isolating diaphragm:316L SST
[2]: Insert tube length (mm):100
[A]: Filling liquidOrdinary silicone oil(-30~200ºC)
[3]: Capillary Length3m
[P]: With PVC protective coating capillary
 
Code 1
TS
Thread mounting type
With capillary, thread type pressure remote installation
Code 2
1
2
Spare flush hole
None
Yes
Code 3
A
B
Remote flange isolating diaphragm
316L
Hastelloy C
Code 4
1
2
Material for upper sleeve & flange
Stainless steel for upper sleeve, galvanized CS for upper sleeve flange
Stainless steel for upper sleeve, stainless steel for upper sleeve flange
Code 5
A
Material for lower sleeve and induced pressure connection port
316 stainless steel for lower sleeve, NP1/2 induced pressure connection port
Code 6
A
B
Filling liquid
Ordinary silicone oil(-30~200ºC)
High temperature silicone oil(-10~350ºC)
Code 7
1
2
3
4
5
6
8
X
Capillary Length
1m
2m
3m
4m
5m
6m
8m
Special length
Code 8
N
P
Capillary protective cover
No
With PVC capillary protective cover
Note: (1) In the choice of remote flange sealing device, you
should firstly complete the selection of ASP2002B Smart
Remote Pressure Transmitter and select in the
ASP2002B intelligent differential pressure transmitter
selection table: Code 5 - R remote options.
(2) The accuracy grade level of level and remote
transmitter is 0.25 class
Example:
Smart Remote Pressure Transmitter
ASP2002BH-4R2N2C-MiP, TS1A2AA3P
[B]: Accuracy: 0.1%F.S
[H]: Output: (4~20) mA & HART
[4]: Measuring range : 0-4.0 ~ 40 kPa
[R]: Process connection : Remote
[2]: Isolating diaphragm:316L stainless steel
[N]: O-ring material process flange:
Perbunan(NBR)
[2]: Mounting Bracket: Stainless steel bracket
[C]: Nameplate: In Chinese
[M]: LCD display meter
[i]: Intrinsic safety Ex ia II C T4~T6
[P]: Stainless steel tag label
[TS]: With capillary, thread type pressure remote
installation
[1]: No release valve
[A]: Remote flange isolating diaphragm:316L
[2]: Stainless steel for upper sleeve, stainless
steel for upper sleeve flange
[A]: 316 stainless steel for lower sleeve, NP1/2 induced
pressure connection port
[A]: Filling liquid: Ordinary silicone oil(-30~200ºC)
[3]: Capillary Length: 3m
[P]: With PVC protective coating capillary

SGS & TUV Audited Factory
Single Flange Smart Pressure Transducer/Transmitter
Single Flange Smart Pressure Transducer/Transmitter


ISO9001:2015 & CE
Single Flange Smart Pressure Transducer/Transmitter

Ex ia & Ex d Certificates
Single Flange Smart Pressure Transducer/Transmitter




FAQ:
1. Q: Are you manufacturer or trading company?
A: We are A professional manufacturer of Pressure/Temperature sensor, wireless transmitters, gateways, even the total solutions of IIOT for more than 11 years in China. With 4~20mA, Hart, Rs485 & Modbus protocols, pressure sensors with 4~20mA, 0.5~4.5V, UARTand etc, also wireless IOT measurement transmitters. We provide high quality products with high competitive factory price.
 
2. Q: What's your quality control system?
A: As an ISO9001:2008 certificated manufacturer, we have strict quality control system, and each product is done fatigue testing, calibration, temperature compensation before shipment. High quality is guaranteed.
 
3. Q: Is there MOQ with your product?
A: We have no MOQ limits, 1pc for testing is acceptable.
 
4. Q: Do you provide customized products?
A: Yes, we can print your logo on our products; OEM, ODM & customization are welcomed.
 
5. Q: What is the warranty of your products? And after-sales service?
A: Our warranty time is 12 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.
 
6. Q: What is lead time of your product?
A: We are factory, our lead time is always within 10~15 working days for products without customization, but lead time will vary based on different products. You can check detail lead time with our sales.

7. Q: What international certificates do you have for your products?
A: we have gained CE, RoHs certificates, and are in the process of gaining ATEX & UL certificates now.

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours