Product DescriptionXMT908 intellectual ability temperature controllerIntelligence industrial regulation instrumentA high performanceXMT-908 intelligence-ability temperature controller is a kind of high performance & reliability intelligence-ability temperature control meter, they are widely used in the automatic contro

Featured Products

Product Description
XMT908 intellectual ability temperature controller
Intelligence industrial regulation instrument
A high performance


XMT-908 intelligence-ability temperature controller is a kind of high performance & reliability intelligence-ability temperature control meter, they are widely used in the automatic control system of the temperature, chemical, ceramics, light, metal, petrochemical and heat treatment industry

Main technical specification 
1. Measurement deviation: ≤ ± 0.5%FS± 1.
2. Sampling cycle: 0.5S.
3. Control cycle: Relay output 2~120S, other is 2S...
4. Relay output contact capacity: AC250V/7A (resistance load) or AC250V/0.3A (perceptual load).
5. Driving controllable pulse output: ≥ 3V scope, ≥ 40us width's over zero or trigger contact pulse.
6. Driving solid relay signal output: Driving electric current≥ 15mA, voltage≥ 9V...
7. Continuous PID: 0~10mA (load 500± 200Ω ), 4~20mA (load 250± 100Ω ), or 0~5V (load≥ 100kΩ ), 1~5V (load≥ 100kΩ ).
8. Power supply: AC90V~242V, 50/60Hz.
9. Working condition: Temperature 0~50.0, relative humidity≤ 85%RH, without corrode and strong electric radiation.
10. Exterior and hole size(mm): 160× 80× 120 152× 76;

Meaning of the model code
   XMT _ -  9   _   8   __
              (1) (   2)   (3)  (4)    (5)
(1)The surface dimension(mm):
Blank:160×80×120 Installation hole 152×76; 
A:96×96×110 Installation hole 92×92;
D:72×72×110 Installation hole 68×68; 
E: 48×96×110 Installation hole 44×92; 
F:96×48×110 Installation hole 92×44; 
S:80×160×120 Installation hole 76×156
G:48×48×110 Installation hole 44×44 
(2)Control Mode: '9':4-key gentle push-switch setting,double row 4-LED digital display,PID and ON/OFF(P=0)control can select. 
(3)Additional alarm:'0':no alarm ; '1':one group alarm; '3':two group alarms '5':voice alarm
(4)Signal input type:'8':freely exchange signal 
(5)Suffix:
Main control output method:
'Blank':relay's open and closed contact output;
'A':Single-phase over-zero spark pulse; 
'A3':Three-phase over-zero spark pulse;
'B':Single-phase shift-phase spark pulse; 
'B3':Three-phase shift-phase spark pulse;
'C':0~10mA or 4~20mA constant electric current output 
'G':ON/OFF solid state relay(SSR)adjustment output;
Auxiliary ways:
'K':with RS485 or RS232 communication module interface; 
'Wt':with micro-printer output signal;
 
Inner parameter
SeriesCodeNameSetting rangeManual Ex-Factory
0SPSetting value of temperatureDetermined by P-SL P-SHOutput corresponds to "OUT" indicator light50.0
1AL1Alarm 1Determined by P-SL,P-SH when the upper and lower limit alarm, it is0~50.0 when the positive deviation alarm and negative deviation alarm 
please refer to ALP1
Corresponds to "ALM1" indicator light
300
2AL2Alarm 2
 
please refer to ALP2
Corresponds to "ALM2" indicator light
100
3PProportion modulus0~100When the P↑, the proportion and differential
function↓; If the P↓, the proportion and 
differential function↑
When P=0, the meter is ON/OFF control
15
4ICalculus time0~2000S
 
240
5dDifferential time0~200S
 
30
6AtSetting itselfON/OFFON: open setting itself function
OFF: close setting itself function 
OFF
7tControl period1~120SThe movements cycle ON/OFF of Setting relays control is no meaning,
Relay is 20S,  other is 2S.
20
8HyMain control by
drop in level
0.1~50.0Only have meaning when main control output is ON/OFF(P=0)1.0
9Hy-1drop in level
 of  AL1
0.1~50.0It is used as setting of drop in level
for AL1 relay output  
1.0
10Hy-2drop in level
of  AL2
0.1~50.0It is used as setting of drop in level
for AL2 relay output  
1.0
11PbSensor error amendment±20.0The sensor have deviation can use item to revisal0
12FILTFilt modulus0~50Is the software filter constants of  measurement sampling. The constant ↑, the measurements antijamming capability↑, but the measurement and system time ↓.20
13dpDisplay precision0~11: have radix point; 0: have not radix point0
14P-SHThe max.value of temperature range-They are used to reset proper temperature range as per user'application.
As for the Max. temperature range for
different inputs, please refer to Sn,
P-SH≥P-SL
1300
15P-SLThe min.value of temperature range-
 
0
16OUTLThe min. value 
of allowable output  
0~OUTHCan achieve low and high output limiter. Meaningless when manual and ON/OFF control0
17OUTHThe max. value 
of allowable output
OUTL~200
 
200
18ALP1Alarm1  and output definition0~4'o':indicate no alarm;  '1':upper limit alarm
'2':lower limit alarm; 
'3': Upper-limit (deviation) Alarm;
'4': Lower-limit (deviation) Alarm;
-
19ALP2Alarm2  and output definition0~4
 
-
20COOLSystem function choice0~1'0': reverse control(heat)
'1': positive control(cool)
0
21OPPOOpen power output0~100Soft start functionthat meters coefficient after first export of electric power0
22LOCKCode lock0~50LOCK=0, all the parameter can be revised
LOCK=1, only the SP can be revised
LOCK>1, all the parameter can not be revised
0
23SnInput typeCU50( )
PT100( )
PT100( )
K( )\E( )\J( )
T( )\S( )
CU50 (-50.0~150.0ºC) ;
PT1 (-200.0~200.0ºC) ; 
PT2 (-200.0~600.0ºC) ;K (0~1300ºC) ; 
E (0~700.0ºC) ;      J (0~900.0ºC) ; 
T (-200~400.0ºC) ;   S (0~1600ºC) ;

 
24OP-AOutput type 
RLP( )
SSR( )
Zero( )
Mut( )
0~10MA( )
4~20MA( )
RLP Relay output mode
SSR Solid state relay
Zero   SCR zero voltage switching
Mut   SCR phase-shift trigger
0~10MA linearity  control electric current output
4~20MA  linearity  control electric current output
 
__

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours