Capacitive Level/Differential Pressure Transmitter Sensors

Pressure sensor- manufactured from Tianjin U-ideal instrument Co., Ltd, is our main producing pressure instrument. we have pressure switch, pressure transmitter, pressure gauge, pressure sensor, capacitance pressure sensor, DP pressure transmitter.....inductive pressure sensor, piezoresistive pressure sensor, semiconductor strai

Featured Products

Pressure sensor- manufactured from Tianjin U-ideal instrument Co., Ltd, is our main producing pressure instrument. we have pressure switch, pressure transmitter, pressure gauge, pressure sensor, capacitance pressure sensor, DP pressure transmitter.....inductive pressure sensor, piezoresistive pressure sensor, semiconductor strain gauge pressure sensor, resistance strain gauge pressure sensor

Pressure based transmitter Main products:

Pressure transmitter
T20 series pressure transmitter/pressure sensor
T51GP pressure transmitter
T61GP pressure transmitter/pressure sensor
T61TGP pressure transmitter
T61AP absolute pressure transmitter

Differential Pressure transmitter
T51DP Differential pressure transmitter / pressure sensor
T51HP high hydrostatic differential pressure transmitter
T51DR micro differential pressure transmitter
T51DP/GP remote sensor differential pressure transmitter
T61DP differential pressure transmitter
T61HP high hydrostatic differential pressure transmitter
T61DR micro pressure transmitter / pressure sensor
T61C
T61DP/GP remote sensor differential pressure transmitter

Liquid Level Transmitter
n T20L drop-in cable level transmitter
n T20L insert rod type level transmitter
n T20Y flanged level transmitter
n T20D press-guiding level transmitter
n T20M diaphragm level transmitter
n T51LT flanged level transmitter
n T61LT flanged level transmitter
n T61Y pressure vessel level transmitter
T61W sanitary type pressure sensor

Flow Transmitter
n T51 flow transmitter
n T61 flow transmitter
n T61S flow transmitter
n T61C flow transmitter


UI-P61 Series Capacitance type intelligent transmitter

 
UI - P61 Ordinary structure differential pressure, gage pressure and absolute pressure transmitter
l   Accuracy 0.1%; Ratio: 50:1
l   Measure pressure Range from 100 Pa to 40 MPa
l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
l   Light, small, easy to install
 
 
 

UI - P61C Integrated structure differential pressure, gage pressure and absolute pressure transmitter
l   Accuracy 0.1%; Ratio: 50:1
l   Measure pressure Range from 100 Pa to 40 MPa
l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
l   Flanged integrated structure, Good design is durable, no leakage;
l   Light, small, easy to install
 
 
 
 
UI-P61T Directly mount gauge pressure, absolute pressure transmitter
l   Accuracy 0.1%; Ratio: 50:1
l   Measure pressure Range from 100 Pa to 40 MPa
l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel.
l   Light, small, easy to install;
 
UI-P61 LT Level transmitter
l   Accuracy 0.2%; Ratio: 15:1
l   Flat diaphragm or 50mm, 100mm, 150mm, 200mm inset diaphragm.
l   Various filling liquid to suit strict temperature.
l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
 

UI-P61 Remote pressure /differential pressure transmitter
l   Accuracy 0.2%; Ratio: 15:1
l   Flat diaphragm or 50mm, 100mm, 150mm, 200mm inset diaphragm.
l   Suit stricter temperature.
l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
 

UI-P61W sanitary pressure transmitter
l   Accuracy 0.2%; Range ratio: 15:1
l   Various process mounting type..
l   Various filling liquid to suit various sanitary conditions.
l   Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
 
 
 
UI-P61Y pressurized container special using drop-in type level transmitter
Accuracy 0.2%; Range ratio: 15:1
Various process mounting type.
Various filling liquid to suit strict temperature.
Process isolation diaphragm: 316L stainless steel, Hastelloy, tantalum, Monel or 316L lined with PTFE.
Capacitance Level / Differential Pressure Transmitter SensorU-ideal´s 3351(&1151) 3051DP differential pressure transmitter provides a kind of reliable measuring way. It is used for measuring differential pressure (or pressure), level, density of liquid, gas or steam and convert the value of above into current signal output or digital protocol output. The pressures are directly applied to the isolating diaphragm that provide isolation and resistance against process fluid corrosion. Being microprocessor based, the electronic circuit is extremely versatile and accurate. Combined with the sensor precision, it provides the high accuracy and range ability. Transmitter performance is improved by continuous monitoring of the sensor temperature and corresponding corrections. A local display permits easy reading and writing of data.
 
The Model 3351 design is offered for Differential Pressure (DP), Gage Pressure (GP) and Absolute Pressure (AP) measurements. The Model 3351utilizes capacitance sensor technology for DP measurements. The major components of the Model 3351 is the sensor module and the electronics housing. 

TECHNICAL SPECIFICATIONS
Super measuring performance, used for pressure, differential pressure, liquid level, flow measure, 
High accuracy: digital accuracy + (-) 0.05%; Simulation accuracy + (-)0.5% +-~ 0.1% F.S range.
Zero and span external continuous adjustable; range: 100:1.
Positive transfer up to 500%, negative transfer to 600%.
Stable performance, stability: 0.25% 60 months.
Overpressure resistant.
Solid sensor design.
A full serious of unified structure, strong interchangeability.
Optional contact medium diaphragm material.
Low pressure casting aluminum alloy shell.
Measuring rate: 0.2 s. 
Connection is compatible with other products, to achieve the best measurement.
Adopt 16 computer intelligent transmitters.
Standard 4-20 mA, a digital signal based on HART protocol, remote control. 
 
 
Parameters 
Using object: liquid, gas and steam; 
Power supply voltage: 12 ~ 36 v DC, standard 24 VDC; 
Output signals: 4 ~ 20 mA DC; ( 4-wire 220V AC power supply 0 ~ 10 mA DC output special)
Ambient temperature: 25 ~ 70 ºC (transmitter), 15 ~ 70 ºC (with the indicator). 
Measure temperature: - 40-104 ºC, flange pump silicone oil filling - 40-104 ºC, high temperature silicone oil filling 15-315 ºC.
Storage temperature: - 40 ~ 100 ºC; 
Relative humidity: 0-100% RH, 
Protection grade: d II BT4, ia II CT5; 
Power effect: less than the output range of +/- 0.005% / V; 
Vibration: vibration 200 Hz in any direction, the error is to 0.05% of the maximum range/g (micro differential pressure is 0.25%/g); 
Installation location effect: when the work diaphragm is vertical installation, may be no greater than 0.24 Pa zero error, error can be eliminated by adjusting the zero, won't impact range; 
Stability: six months less than the precision of the transducer; 
Indicator: linear indication 0 ~ 100%; 3-1/2 LCD.
Range and zero: external continuous adjustable
Positive and negative migration: the most-positive migration amount was 500%, the largest amount of negative transfer of 600%
Material : 
Isolation diaphragm: 316 SS, Hartz-C type alloy, monel alloy, Tantalum
Vent/drain valve: 316L stainless steel, ha - C type alloy, monel alloy
Flange and fittings: 316L stainless steel, Hartz - C type alloy, monel alloy
"O" type circle: fluorine rubber
Inert filling liquid: silicone oil
Bolt: 316L stainless steel
Electronic shell: low copper aluminum alloy
 
 
ModelTransmitter Type(Single selection)DPHPGPAP
3051DPDifferential Pressure transmitter.---
3051HP High pressure Differential pressure transmitter-.--
UIP-T62GPGauge Pressure--.-
3051AP Absolute Pressure---.
CodePressure Measure range(URL)(Single selection)DPHPGPAP
31.3~7.5kPa...-
46.2-37.4kPa....
531.1-186.8kPa....
6117-690kPa....
7345-2068kPa....
81170~6890kPa.-..
93480~20680kPa--.-
06890~41370kPa--.-
CodeTransmitter output (single selection)DPHPGPAP
E 4-20mA,Linear, Analog /damping adjustable....
N 4-20mA, digit intelligent type....
S4-20mA,intelligent, HART protocal....
Codeflange & Jointsdrain/ventdiaphragmDPHPGPAP
22316SS316SS316L SS....
23316SS316SShastelloy C....
24316SS316SSMonel Alloy....
25316SS316SStantalum....
33hastelloy Chastelloy Chastelloy C....
35hastelloy Chastelloy Ctantalum....
44Monel AlloyMonel AlloyMonel Alloy....
CodeIndicator (If don't need local display, don't select)DPHPGPAP
M1 Analog Scale, Linear head, 0-100% scale....
M2Analog Scale, square root      showing, 0~10 scale..--
M3 LCD, linear head, 0-100% selectable....
CodeMounting bracketDPHPGPAP
B1Tube bending plate ( tube outside diameter Φ50~60)....
B2Plate bending plate....
B3Tube flat plate ( tube outside diameter Φ50~60)....
CodeRelease valveDPHPGPAP
D0Drain valve at the back....
D1Side Release valve above the pressure chamber....
D2Side Drain valve at the bottom of the pressure chamber....
CodeLow pressure side Flange adaptorDPHPGPAP
N no flange adapter (with 1/4NPT female at flange to connect the press-leading lines)....
C1 1/2NPT female screw flange adapter, connect pilot pressure joint and welding press-leading tube(stainless steel) ....
C2 M20x 1.5 Male screw flange adapter, connect pilot pressure joint and welding press-leading tube(stainless steel)....
CodeExplosion-proof (don't select is standard type)DPHPGPAP
d explosion-proof Exd II CT6....
iIntrinsically safety Exia II CT6....
Typical model:  3051DP 4 S 22 M3 B3 D2 C2
Capacitance Level / Differential Pressure Transmitter SensorCapacitance Level / Differential Pressure Transmitter Sensor
Performance & technique parameter
 (Reference conditions: no zero migration, silicone oil filling, 316L diaphragm)
The output signal: 4-20 mA two-wire system;
Accuracy:
Linear output: ±0.1% (to range ratio 1:1}, including linear, variation, the repeatability general error.
Extraction of root output: when the output pressure is 4-100%, is (0.2% of Calibrated range + 0.05% at biggest).
Stability: for DP range code 3, 4, 5, stability is ±0.2% of the highest range. For other range code, stability is ±0.25% of the highest range.
Humidity: 0-100% relative humidity;
Start time: At minimum damping, 2 seconds at most.
Volume drain: <0.16 cm3
Damping: electrical damping is 0 to 32s. In addition, the sensitive element have 0.2s Constant damping time (range 3 is with 0.4 seconds);
Static pressure effect (DP transmitter)
Zero error: If 10 Mpa, zero error is 0.25% of the highest range; for range which code is 3, zero erro is 0.5% of the highest range; zero point can be corrected through the zero adjustment.
Temperature influence:
The zero error at the biggest range:
±0.5% every 56 ºC; total influence include span and zero error, ±1% every 56 ºC; for range which code is 3 in model table, the influence is times of above range;
For the smallest measure range zero error, ±0.5% every 56 ºC; total influence include span and zero error, ±3.5% every 56 ºC; for range code 3 in model selection, the influence is times of above range;
Vibration impact: Frequency is o - 200 HZ, each g is ±0.05% up limit at any direction.
Power supply: < 0.005%/V of calibration range.
Installation position influence: zero drift <0.25 KPa, the error can be eliminated by correction, so without impact to range.
Electromagnetic interference/radio frequency interference: according to SAMA PMC33.1, test from 20-1000 Hz, field intensity can be up to 30V/m.
Standard structure
Wet parts materials
Isolation diaphragm
316L, Hastelloy C - 276, monel or tantalum, each types optional materials, see to the order information table.
Drain/air valve
316L, Hastelloy C - 276, monel. Each type optional material, see to the order information table.
Wet O-rings: Teflon
Non-wet parts material:
Liquid filling: Silicon or Inertia fluid
Bolts and flange with bolts: galvanized carbon steel;
Electric shell: Low copper aluminum;
Spraying: polyurethane (PU)
Gauge cover O ring: NBR (nitrile rubber Buna)
Process connection port:
1/4 ~ 18 NPT: Range 3, 4 and 5, flange distance: 54 mm
1/4 ~ 18 NPT: Range 6 and 7, flange center distance: 56 mm
1/4 ~ 18 NPT: Range 8, flange center distance: 57 mm
Range 3, 4 and 5, Flange joint can be rotated, in order to realize the 51 mm,
54 mm or 57 mm center distance.
Electrical connections
1/2~14 NPT or M20X1. 5 conduit entrance; weight: 2.4 kg
Conditions of use
Overall protective performance: IP67
Power supply voltage:
12V - 45VDC intrinsic safety products, power supply should through safety barrier firstly. (Standard is 24 VDC, if no load can work at 12VDC, with LCD header power should be not less than 16 VDC)
Products application environment
Temperature: - 20ºC~+80ºC, storage temperature: - 40ºC - + 104ºC; humidity: 0-90%
Explosion-proof products using environmental conditions:
Temperature: - 20ºC - + 40ºC; relative humidity: 5% ~ 95%.
Atmospheric pressure: 86-106 KPa
Intrinsic safety production matched safety barrier parameters:
Uo ≤28r DC; Io≤30mA
 
 

UI-P61 series intelligent pressure / differential pressure transmitter

General introduction:
Application:
UI-P61 series pressure/ differential pressure transmitter have many different types which are used to measure differential pressure, flow, gauge pressure, absolute pressure, vacuum degree, liquid level and specific gravity. Read carefully the order instruction table to confirm us the transmitter model, pressure range, signal output type and transmitter's structure materials.
 
Working principle:
When work, the high and low pressure side diaphragm and filling liquid pass the pressure to the center of filled liquid, the center filled liquid passed the pressure to center diaphragm ofδchamber sensor, and the sensing diaphragm is a tension elastic element, the displacement changed by the differential pressure ( GP gauge pressure transmitter, atmospheric pressure is like exert the pressure on the low pressure side of the sensing diaphragm; AP absolute pressure transducer, low pressure side always keep a reference pressure). The largest displacement of diaphragm is 0.1 mm, and the displacement is proportional to the pressure force. The capacitor plate on both sides sense the diaphragm position. The differential capacitance value between Sensing diaphragm and electrical capacitor plate is transferred into the corresponding current, voltage or digital HART output signal.
PCB module
The transmitter PCB module adopts special using Integrated Circuit (ASICS) and surface sealing technology. When the PCB received the digital signal from sensor diaphragm and coefficient corrected correct the signal and linearizing it. PCB output the digital signal to analog signal output and communicate with Hart operator. Is insert the LCD head to the PCB, then the transmitter can display the pressure unit and percentage unit digital output.
The data configuration
The configuration data stored n the transmitter circuit board EEPRQM permanent storage. So the Transmitter still can save the data even power off. Therefore the transmitter can work immediately once power on.
Digital / Analog converter and signal transmission
Process Variable is stored by data mode. Can be fine corrected and engineering unit converting. Then the corrected data is converted into analog signal output. The HART operator can store the sensor digital signal directly with higher accuracy which don't need digital / analog converting again.
Software function:
HART protocol make user easily to configure, test and set the UI-P61 series transmitter.
Communication Mode
UI-P61 series pressure/differential pressure transmitter adopts HART protocol communication.
The protocol adopts the industrial standard Bell202 frequency shift keying (FSK) technology, superimposed a high frequency signal on the current output signal to realize the remote communication. This technology can make the transmitter communication and output at the same time and without influence the Loop consistency.
The configuration
UI-P61 series pressure/differential pressure transmitter can be easily configured with HART hand operator. The configuration includes two Aspects. First. The transmitter operational parameter Settings, include Settings:
l   Zero and span set
l   Linear output or square root output
l   Damping,
l   The engineer unit selection
The second, the informational data of transmitter deposited in the transmitter which to recognize the transmitter and make physical description for the transmitter. These data include:
l   Location number: 8 letters, number and characters
l   Descriptors: 16 letters, number and characters
l   Information: 32 letters, number and characters
l   Date & integrated transmitter head installation
l   Flange type, and flange material
l   Drainage/exhaust valve materials & O ring material
l   The remote parts material information
In addition to the above, the software also contains many non users can modify information: the transmitter types, sensor limited, the minimum range, filling liquid,  the diaphragm material, diaphragm head serial number and software version number.
 
Test
UI - P61 series pressure/differential pressure transmitter can do self-inspection consecutively. If problems found, transmitter will activate the users optional analog output alarm, can check the problem with HART hands operator to determine the problem. Transmitter output specific information to the HART operator to help identifying the problem and maintenance immediately. If the operating personal convinced that the problem is come from circuit return, the transmitter can provide the specific output by asking which is for use of loop test.
The specific Settings
Specific Settings for transmitter first time setting and the digital PCB maintenance. It allows fine adjustment to the sensor and the analog output to meet factory pressure standards. In addition, the characteristic function avoid the user accidental or intentional adjusting the setting point of analog output.
 
Technique information
Medium: Liquid, air or Steam
Output: 4~20mA DC, user can select linearity or square root output digital process variables added to 4~20mA signal. Are available on the HART protocol used on microcomputer.
Power supply
Require outer power supply. Working power is 12~45VDC when transmitter without load.
 
VminVmaxRminRmaxRL at Power Vs
12V45V0'Ω1650'ΩR1=(Vs-12)/0.02
 
 
 
Span and Zero
Can adjust the Span and Zero through the transmitter or by HART operator remote adjustment.
Zero positive and negative shift
When Zero negative shift, the range low limit must be - URL;
The zero positive shift must be ≤+ URL.
Test range must the minimum span.
Temperature limit
PCB operating temperature: -40 to 80º;  
The sensor working temperature: filling silicone oil: -40 to 104ºC
Filling liquidTemperatureSpecific gravity
g/cm
coefficient of
thermal expansion
viscosity
at 25ºC
200# silicon-40~149ºC0.9340.001089.5
high temperature silicon oil15~315ºC1.070.0005344
Inertia oil-45~205ºC1.850.00086465
 
Humidity limit: 0~100% relative humidity
Volume changing: <0.16cm3
Fault alert
Self-diagnostic function detected the transmitter failure, then analog signal is output by lower than 3.9mA or higher than 21mA to alert user. The high or low alarm signal can be selected by user.
Electric Level4~20mA saturation value4~20mA alert valve
low3.9mA3.8mA
high20.8mA21.72mA
 
Transmitter protection
Use transmitter protection function can prevent changes the transmitter configuration, including preventing the device zero and span adjustment. Protect function can be set by internal switch.
Over voltage alarm
If the transmitter output a negative overvoltage, then the analog signal output 3.9mA; If the transmitter output an positive over voltage value, the analog signal output 20.8mA.
Damping
Silicone oil filling at room temperature, the electrical damping is 0~32seconds.The smallest time constant is 0.1 seconds (range 3 is 0.4 seconds).
High temperature silicone oil filling transmitter, this value will be higher.
Performance parameter
(The zero base calibration range, reference conditions, silicone oil filling, 316L isolation diaphragm)
Accuracy (including linear, variation, repeatability total error)
Range code from 4 to 8, DP and GP transmitter;
Range code 4 to 7, HP transmitter
±0.1% of calibration range;
±0.1%+ (0.01range high limit / range)% (more than 10:1 range ratio).
Other range and model transmitter ±0.25% of calibration range
The stability
DP and GP model, the range mode 4 to 8: ±0.1% URL, 12 months;
Other range and model transmitter: 0.25% URL, 12 months.
 
Temperature influence:
DP and GP transmitter, measure range code from 4~8;
HP transmitter, measure range code from 4~7.
Zero error=±0.2% URL/56ºC
Total error=±(0.2% URL+0.18% calibration range)/56ºC
Other measure range and model transmitter the temperature influence times higher.
 
Static pressure influence
DP series transmitter
Zero error
For measure range code from 4~8, at 10 Mpa, zero error is ±0.25% URL; for measure range code is3, the error ±0.5%URL; zero error can be corrected through the zero adjustment on line.
Span error
Can be corrected to ±0.25% of input reading value / 6.8MPa
For measure range code is 3, the span error can adjusted to ±0.5%.
 
HP (high pressure) transmitter
Zero error
At 32Mpa static pressure, zero error is ±1% URL; Zero error can be corrected through the zero adjustment on line.
Span error
Can be corrected to ±0.25% of input reading value / 6.8MPa
 
Vibration impact: Frequency which is less than 200 HZ, the impact is ±0.05% URU/g at any direction.
Power impact: < 0.005%/V output range / volt.
Electromagnetic interference/radio frequency interference: according to SAMA PMC33.1, test from 20-1000 MHz, field intensity can be up to 30V/m, the output shift is less than 0.1% of span.
Installation position influence: zero drift <0.25 KPa,
When the liquid level diaphragm vertical mounting the zero drift is less than 0.25KPa,
when the liquid level diaphragm is horizontal installing the zero drift is less than 1.25KPa which plus the extended part length.
All the error can be eliminated by correction on line, so won't impact to range.
 
Structure specifications:
Wet parts materials
Isolation diaphragm 316L, Hastelloy C, monel or tantalum.
Drain/air valve 316L, Hastelloy C, monel.
Wet O-rings: Viton, NBR, PTFE or metal sealing ring.
Non-wet parts material:
Liquid filling: Silicon or Inertia fluid
Bolts and flange with bolts: galvanized carbon steel or 316SS;
Electric shell: Low copper aluminum;
Spraying: polyurethane (PU)
Gauge cover O ring: NBR (nitrile rubber Buna)
Process connection port:
1/4 ~ 18 NPT: Range 2~ 5, flange distance: 54 mm
1/4 ~ 18 NPT: Range 6 and 7, flange center distance: 56 mm
1/4 ~ 18 NPT: Range 8, flange center distance: 57 mm
Range code 2~ 5, Flange joint can be rotated, in order to realize the 50.8 mm,
54 mm or 57.2mm center distance.
Electrical connections
1/2~14 NPT or M20X1. 5 conduit entrance; with bolts ends
Explosion-proof class: explosion-proof Exd II BT6 or intrinsically safety Exia II ct4
Weight: if don't include accessories, the AP, DP, GP, HP models weight is 2.4kg.
Power supply voltage:
12V - 45VDC intrinsic safety products, power supply should through safety barrier firstly. (Standard is 24 VDC, if no load can work at 12VDC, with LCD header power should be not less than 16 VDC)
Products application environment
Temperature: - 20ºC~+80ºC, storage temperature: - 40ºC - + 104ºC; humidity: 0-100%
Explosion-proof products using environmental conditions:
Temperature: - 20ºC - + 70ºC; relative humidity: 5% ~ 95%.
Atmospheric pressure: 86-106 KPa

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours